Product Description
Specification
Model
MS510IT/MS510S
MS520IT/MS520S
Bandwidth(BW)
100MHz
200MHz
Rise time
≤3.5ns
≤1.5ns
Real time sampling rate
single channel: 1GSa/s, dual-channels: 500MSa/s
Memory depth
single channel: 240Kpts, dual-channels: 120Kpts
Isolated channel
support
Max waveform capture rate
190,000 wfms/s
Vertical system
Channels
2 oscilloscope channels,1 multimeter channel
Limited bandwidth
20MHz
Coupling modes
DC,AC,GND
Input impedance
parallel 1MΩ±1% with 15pF±3pF
Vertical sensitivity range
5mV/div~50V/div
Vertical resolution
8bits
Max voltage input
600V CAT Ⅱ 300V CAT Ⅲ
Floating voltage from CHs to GND
1000V CAT Ⅱ 600V CAT Ⅲ
DC vertical gain accuracy
5mV/div~50V/div, 2.0%
Horizontal system
Timebase
2ns/divs~10s/divs
Timebase delay range
-12divs~50s
Timebase accuracy
20ppm
Sample mode
normal average, pk-pk envelope
Dynamic record
max 2 hours
Store waveform
support internal waveform storage and flash disk storage
Trigger system
Trigger types
edge, pulse, logic, vedio (PAL,NTSC,SECAM,720P,1080I,1080P)serial bus(UART,LIN,CAN,SPI,I2C)
Trigger coupling
DC,AC,High-frequency suppression,Low-frequency suppression, Noise suppression
Trigger modes
auto, normal, single
Trigger source
CH1,CH2,external
Trigger inhibition range
200ns~10s
Measurement
Automatic measurements
31 types
Cursor types
horizontal cursor, vertical cursor, cross cursor
Math
Operator
+ , – , * , /
FFT window settings
Rectangular, Hamming, Blackman-Harris, Hanning
Display features
Display screen
5.7 inch TFT LCD touch screen
Resolution
640*480
3D waveform display
not support
Grid of waveform display zone
horizontal 12 divs * vertical 8 divs
Form
YT mode or XY mode
Interpolation method
sin(x)/x
Persist
auto, 100ms~10s or ∞
I/O port
Mini USB2.0
connect to PC
USB2.0
connect to Flash disk
Multimeter
Multimeter type
13 physical measurements ,such as voltage, current, resistance, capacitance, diode , etc
Multimeter accuracy
5,000 counts
Multimeter display
max, average, min, values with time stamp; relative measurement
Data Logger
Logger content
multimeter measurements, oscilloscope measurements, oscilloscope waveforms
Logger timebase
multimeter measurements,10s/div ~ 20min/div
oscilloscope measurements 10s/div ~ 20min/div
oscilloscope waveform 100us/div ~ 2min/div
Logger time length
49s~ ∞
Power
Power adapter
Input:100-240VAC,50-60HZ,2A; Output: 12VDC,5A
Battery
capacity:7.4V/6000mAh, Work time:4~5 hours
Work environment
Temperature
-20℃ ~ +50℃
Humidity
< 85%RH
Dimension
Size
254mm*160mm*60mm
Weight
main unit: 1380g (no battery), accessories(standard): 691g,battery(standard): 276g
Standard accessories
Quanity
Remark
Probe
2
MC probe; isolated 250MHz probe
Banana jack
1
Multimeter test leads
1
Power adapter
1
Standard battery
1
6000mAh Li-ion
USB Cable
1
Random CD
1
Including user manual, ScopeSuite demo version software, oscilloscope driver and instruction
Optional accessories
Remark
Oscilloscope suitcase
Oscilloscope handbag
High-capacity battery(9000mAh)
LCD protective film
Full functional version of Scope Suite
XY mode
U device function
UART(RS232/RS422/RS485)Serial bus decode function module
“MT510IT, MT520IT”
LIN Serial bus decode function module
“MT510IT, MT520IT”
CAN Serial bus decode function module
“MT510IT, MT520IT”
SPI Serial bus decode function module
“MT510IT, MT520IT”
I2C Serial bus decode function module
“MT510IT, MT520IT”
1553B Serial bus decode function module
“MT510IT, MT520IT”
429 Serial bus decode function module
“MT510IT, MT520IT”